Dometic Brisk Air 2 User Manual

BRISK AIR II COOL ONLY The Dometic Brisk II Rooftop Air Conditioner is the next generation of one of the most popular and imitated RV air conditioners. Stronger, light - er, smaller and more environmentally friendly than the previous version, the Brisk II features tighter specification tolerances and improved materials to maximize air flow. Duo-Therm 579 Series BRISK AIR Manuals & User Guides. User Manuals, Guides and Specifications for your Duo-Therm 579 Series BRISK AIR Air Conditioner. Database contains 3 Duo-Therm 579 Series BRISK AIR Manuals (available for free online viewing or downloading in PDF): Installation & operating instructions manual, Installation instructions manual. LaGrange, IN 46761. 579 Series BRISK AIR 590 Series QUICK COOL 595 Series QUICK COOL. 2 INSTALLATION AND OPERATING INSTRUCTIONS.

Download Installation instructions manual of Dometic 57908.321 Air Conditioner, Heat Pump for Free or View it Online on All-Guides.com. This version of Dometic 57908.321 Manual compatible with such list of devices, as: 57915.531, 57915.546, 57915.631, 59016.521, 59516.603

Brand: Dometic

Filename Date Modified Size; Brisk-Air-ACinstallationEN.pdf: 20 Aug 2013 18:30: 673.8 Kb: Dometic AC models and accessories.pdf: 03 Feb 2018 06:50: 1.6 Mb.

Category: Air Conditioner , Heat Pump

Type: Installation instructions manual

Model: Dometic 57908.321 , Dometic 57908.521 , Dometic 57912.531 , Dometic 57912.532 , Dometic 57912.622 , Dometic 57912.631 , Dometic 57915.322 , Dometic 57915.331 , Dometic 57915.336 , Dometic 57915.422 , Dometic 57915.522 , Dometic 57915.531 , Dometic 57915.536 , Dometic 57915.541 , Dometic 57915.546 , Dometic 57915.622 , Dometic 57915.631 , Dometic 57915.731 , Dometic 57915.741 , Dometic 59016.521 , Dometic 59016.531 , Dometic 59016.621 , Dometic 59016.631 , Dometic 59516.303 , Dometic 59516.331 , Dometic 59516.336 , Dometic 59516.501 , Dometic 59516.531 , Dometic 59516.536 , Dometic 59516.601 , Dometic 59516.603 , Dometic 59516.631 , Dometic 59516.731 , Dometic BRISK AIR 579 SERIES , Dometic BRISK AIR 590 SERIES , Dometic BRISK AIR 595 SERIES

Pages: 12 (0.69 Mb)

INSTALLATION INSTRUCTIONS
A.If your installation included the optional electric heat kit,
install it at this time. Follow the instructions with the
B.Terminate the 4-conductor control cable(s) protruding
into the 14-1/4” x 14-1/4” (±1/8”) roof opening. The
cable(s) must be terminated with an RJ-11-4C-6P telephone
connector. Refer to the crimp tool manufacture for
Important:RJ-11-4C-6P connectors must be installed as shown
C.Remove the junction box cover from the Electronic
D.Plug the electrical conduit (6-pin connector) from the
Dometic brisk air 2 user manual download
upper unit into the mating connector in Electronic Con-

Dometic Brisk Air 2 User Manual

E.Plug the control cable(s) into the telephone jack(s) on
the Electronic Control Kit. (It does not matter which
F.Route the Remote Temperature Sensor cable, if appli-
cable, through the same round grommet where freeze
control wires go into the Electronic Box. See FIG. 11.
Connect it to the connector that matches its color.
DometicDometic Brisk Air 2 User Manual
G.Insert the Freeze Control Sensor approximately 1” into
H.Locate the electronic control kit on the ceiling template
as shown in FIG. 13. Drive two (2) #10 x 3/8” blunt point
phillips head screws (provided) through ceiling template
Dometic brisk air 2 user manual pdf
into holes in electronic control kit to hold it in place.
A.CONNECTION OF LOW VOLTAGE WIRES
Disconnect the positive (+) 12 volt DC terminal at the
supply battery. Damage to equipment could occur if
1. Connect the previously run 12 VDC to the red and
black wires protruding from the Electronic Control Kit.
(In multiple zone installations, this needs to be done
at only one zone.) Connect +12 VDC to the red wire;
2. Connect the previously run furnace thermostat wires
(if applicable) to the blue wires protruding from the
Instructions
electronic Control Kit. The polarity of these connec-

Dometic Brisk Air 2 Ceiling Kit

tions does not matter. If not used, terminate wire with
3. Connect the previously run Energy Management
protruding from the Electronic Control Kit. The
polarity of these connections does not matter. If not